Product Information
Categories: BURNERS, OVENPAK 2MAXON burner sleeve gasket is to be installed between the main burner flanges and the oven wall. Designed to provide an airtight seal around the burner flange under the most extreme conditions, the burner sleeve gasket must be installed on all applications with position combustion chamber pressures. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
Related Products
MAXON MIXING CONE – OVENPAK 1
"MAXON mixing cones for the Ovenpak 1 are availble in 3 versions:
- Standard cast iron mixing cone, suitable for most process applications.
- Excess air cast iron mixing cone, allowing +/-10% more air through the burner with the same overall pressure drop.
- Stainless steel mixing cone, suitable for high temperature or highly corrosive applications.
HOUSING GASKET – OVENPAK 2
MAXON housing gasket is to be installed between the two (2) main casing sections of the burner. Designed to provide an airtight seal between the casing pieces, this gasket should provide a worry free seal under a variety of environmental conditions. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
FLAME ROD – OVENPAK 2
MAXON rectification rods (flame rods) have been engineered specially for industrial burner applications. Quality construction provides maximum service life and dependable operation to keep your heating process running smoothly. Consult technical bulletins to ensure your setup is per manufacturer`s recommendation for your specific OP2 model.
DOWNLOADS:
MAXON FILTER ELEMENTS – OVENPACK 1
MAXON red foam filters allow for the removal of particulates from the combustion air stream. The filters are specifically designed for the combustion industry and include a flame retardant to ensure safe operation in a variety of applications.
MAXON PILOT ORIFICE – OVENPAK 1
MAXON pilot orifice valve for the Ovenpak 2 allows for minute adjustments to the pilot capacity to ensure reliable and strong lightoff under a variety of operating conditions.
- Brass body construction.
- 3/8" threaded inlet and outlet connections.
- the orifice is available in both standard and high capacity models.
FIRING SLEEVE – OVENPAK 1
MAXON firing sleeves are available in 5 versions:
- Standard sleeve is 8″ long, made of #310 SS, and is suitable for downstream temperatures up to 1000°F (538°C).
- For higher velocities, specify 12″ long sleeve made of #310 SS for downstream temperatures up to 1000°F (538°C).
- For higher downstream temperatures between 1000°F (538°C) and 1500°F (816°C), specify 8″ long, #RA 330 SS sleeve.
- For higher velocities and downstream temperatures between 1000°F (538°C) and 1500°F (816°C), specify 12″ long, #RA 330 SS sleeve.
- For refractory lined furnaces, specify 8"" refractory lined sleeve. "
MIXING CONE – OVENPAK 2
"MAXON mixing cones are availble in 3 versions:
- Standard cast iron mixing cone, suitable for most process applications.
- Excess air cast iron mixing cone, allowing +/-10% more air through the burner with the same overall pressure drop.
- Stainless steel mixing cone, suitable for high temperature or highly corrosive applications.
MAXON OBSERVATION GLASS – RECTANGULAR – OVENPAK 1
MAXON observation glass allows for proper viewing of flame quality through the back plate of the burner. Includes two (2) sealing o-rings and is available in standard plexiglass or high temperature Quartz models.
CONTROL MOTOR – OVENPAK 2
MAXON Recommended control motors include, but are not limited to the following. Contact PROMAX COMBUSTION for help in selecting the best control motor for your application.
- SMARTLINK DS.
- Honeywell ControLinks.
- Honeywell Modutrol IV.
BURNER SLEEVE GASKET – OVENPAK 1
MAXON burner sleeve gasket is to be installed between the main burner flanges and the oven wall. Designed to provide an airtight seal around the burner flange under the most extreme conditions, the burner sleeve gasket must be installed on all applications with position combustion chamber pressures. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.