BLOWER GASKET – OVENPAK 2
MAXON blower gasket is to be installed on the discharge flange of the integral combustion air blower. Designed to provide an airtight seal around the outlet of the blower flange, this gasket should provide a worry free seal under a variety of environmental conditions. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
BLOWER MOTOR – OVENPAK 1
MAXON blower motors are available in with the following voltages:
230/460/3/60
575/3/60
115/1/60
BLOWER MOTOR – OVENPAK 2
MAXON blower motors are available in with the following voltages:
230/460/3/60
575/3/60
115/1/60
BURNER SLEEVE GASKET – MAXON OVENPAK 2
MAXON burner sleeve gasket is to be installed between the main burner flanges and the oven wall. Designed to provide an airtight seal around the burner flange under the most extreme conditions, the burner sleeve gasket must be installed on all applications with position combustion chamber pressures. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
BURNER SLEEVE GASKET – OVENPAK 1
MAXON burner sleeve gasket is to be installed between the main burner flanges and the oven wall. Designed to provide an airtight seal around the burner flange under the most extreme conditions, the burner sleeve gasket must be installed on all applications with position combustion chamber pressures. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
CONTROL MOTOR – OVENPAK 2
MAXON Recommended control motors include, but are not limited to the following. Contact PROMAX COMBUSTION for help in selecting the best control motor for your application.
- SMARTLINK DS.
- Honeywell ControLinks.
- Honeywell Modutrol IV.
FILTER ELEMENTS – OVENPACK 2
MAXON red foam filters allow for the removal of particulates from the combustion air stream. The filters are specifically designed for the combustion industry and include a flame retardant to ensure safe operation in a variety of applications.
FIRING SLEEVE – OVENPAK 1
MAXON firing sleeves are available in 5 versions:
- Standard sleeve is 8″ long, made of #310 SS, and is suitable for downstream temperatures up to 1000°F (538°C).
- For higher velocities, specify 12″ long sleeve made of #310 SS for downstream temperatures up to 1000°F (538°C).
- For higher downstream temperatures between 1000°F (538°C) and 1500°F (816°C), specify 8″ long, #RA 330 SS sleeve.
- For higher velocities and downstream temperatures between 1000°F (538°C) and 1500°F (816°C), specify 12″ long, #RA 330 SS sleeve.
- For refractory lined furnaces, specify 8"" refractory lined sleeve. "
FIRING SLEEVE – OVENPAK 2
MAXON firing sleeves are available in 5 versions:
- Standard sleeve is 8″ long, made of #310 SS, and is suitable for downstream temperatures up to 1000°F (538°C).
- For higher velocities, specify 12″ long sleeve made of #310 SS for downstream temperatures up to 1000°F (538°C).
- For higher downstream temperatures between 1000°F (538°C) and 1500°F (816°C), specify 8″ long, #RA 330 SS sleeve.
- For higher velocities and downstream temperatures between 1000°F (538°C) and 1500°F (816°C), specify 12″ long, #RA 330 SS sleeve.
- For refractory lined furnaces, specify 8"" refractory lined sleeve. "
FLAME ROD – OVENPAK 2
MAXON rectification rods (flame rods) have been engineered specially for industrial burner applications. Quality construction provides maximum service life and dependable operation to keep your heating process running smoothly. Consult technical bulletins to ensure your setup is per manufacturer`s recommendation for your specific OP2 model.
DOWNLOADS:
GAS INLET GASKET – OVENPAK 2
MAXON gas inlet gasket is to be installed on the gas inlet flange of the burner casing. Designed to provide an gastight seal around the inlet flange of the burner casing, this gasket should provide a worry free seal under a variety of environmental conditions. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
GAS NOZZLE – OVENPAK 1
MAXON gas nozzles are designed for the most rugged industrial applications. Engineered to develop a stable and high turndown flame pattern, nozzles are available for
- NATURAL GAS
- PROPANE
- BUTANE
All nozzles are also available with nickel coating for higly corrosive environments.
GAS NOZZLE – OVENPAK 2
MAXON gas nozzles are designed for the most rugged industrial applications. Engineered to develop a stable and high turndown flame pattern, nozzles are available for
- NATURAL GAS
- PROPANE
- BUTANE
All nozzles are also available with nickel coating for higly corrosive environments.
GUIDE TUBE – OVENPAK 2
MAXON guide tubes allow for the simple installation of either UV flame detection cells of flame rods. Designed to penetrate through the entire burner to visualize the flame directly of the nozzle tip, the carbon steel guide tubes are available with either NPT or TEC end connections.
HOUSING GASKET – OVENPAK 2
MAXON housing gasket is to be installed between the two (2) main casing sections of the burner. Designed to provide an airtight seal between the casing pieces, this gasket should provide a worry free seal under a variety of environmental conditions. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
IMPELLER – OVENPAK 2
MAXON combustion air impellars are built specifically for the Ovepak series of burners. Aluminum die cast, radial blade and balanced for mounting in MAXON integral combustion air blowers, the impellars are available in both ANSI and ISO models.
LINKAGE KIT – OVENPAK 2
MAXON linkage kits allow for the direct coupling of the internal air/gas butterfly valves of the Ovenpak 2 burner series.
The kit includes:
- Butterfly dics
- Linkage arms
- Pins
- Seals
- And bushings to allow fo the complete replacement of the control internals.
MAXON BLOWER GASKET – OVENPAK 1
MAXON blower gasket for the ovenpak 1 is to be installed on the discharge flange of the integral combustion air blower. Designed to provide an airtight seal around the outlet of the blower flange, this gasket should provide a worry free seal under a variety of environmental conditions. The gasket is considered a consumable item and should be replaced during regularly scheduled burner maintenance.
MAXON BRACKET & LINKAGE – OVENPAK 1
MAXON linkage kits allow for the direct coupling of the internal air/gas butterfly valves of the Ovenpak 1 burner series.
MAXON FILTER ELEMENTS – OVENPACK 1
MAXON red foam filters allow for the removal of particulates from the combustion air stream. The filters are specifically designed for the combustion industry and include a flame retardant to ensure safe operation in a variety of applications.